Eaton xy shifter problems.

Truck Maintenance - 98 Century AutoShift problem (Code 51 and 52) - Please help if you can. I have a 98 Century with a 10 sp Eaton Fuller autoshift. Today we replaced the x-y shifter and the transmission still will not shift properly. I had a "-" on my gear dislpay as well as a blinking service light. I

Eaton xy shifter problems. Things To Know About Eaton xy shifter problems.

REMAN XY SHIFTER KIT, EATON FULLER GEN 2 TRANSMISSION, HEAVY DUTY. ABP R26 ... • Suspension Bushings. • Transmissions. • Turbochargers. • Variable Pressure ...1. ORDER THIS KIT TO REPLACE GEN 1 PLASTIC HOUSING ECA, THE KIT INCLUDES ADAPTER HARNESSES & SHIELD, REFERENCE TAIB0862. K-4253RX. GEN 2 ECA KIT (NO HARNESS / NO SHIELD) 125872,K-4253. 1. LATEST DESIGN ECA, CAST HOUSING, THIS KIT DOES NOT INCLUDE ANY HARNESSES OR SHIELD. EATON TRANS HARNESS EATON 4307347 XY SHIFTER K-4118. Harness only, no metal L-shaped bracket. See details - EATON TRANS HARNESS EATON 4307347 XY SHIFTER K-4118. See all 3 brand new listings. Buy It Now. Add to cart. Watch. Sold by pfshd_38 100.0% Positive feedback Contact seller. About this product. Product Identifiers. Brand.You may need to replace your XY shifters, as well as the sensors with better ones to resolve the problem once and for all. But if the XY shifters and sensors are not causing these problems, and yet you …

Oct 17, 2017 · For the price of trying to diagnose the problem by throwing a xy shifter, new clutch, new tcm, labor etc. you're already invested half towards a manual transmission conversion. boneebone , Oct 18, 2017 We have replaced the XY Shifter as well as the 3 Speed sensors & are still having issues with the truck locking in 10th gear & won't downshift - would... Log in or Sign up Forums Forums Quick Links Search Forums Recent Posts Trucking Jobs Truck GPS Reviews CDL Practice Tests Schools Freight Factoring Trucking Insurance Menu Useful SearchesEaton has a great troubleshooting manual. If you are not shifting from low to high or from high to low, check the input sensors or the Range Solenoid Valve. I had the same problem, sometimes it would shift from 2 to 10 then when it got hot, in about 10 minutes, it would not shift. Sometimes stayed in high gear.

Step A: XY Shifter Identification . Pre-April 2009 built XY’s can be identified by the painted motor and end caps, and are not affected by the recent issues. These XY’s should NOT be replaced under this program. Continue to Step V. XY’s built April 2009 through September 15, 2010 can be identified by the chromate (unpainted) motor and end ...

S2745R Fuller Reman XY Shifter Assembly. $1,751.47. Add to Cart. Quick view. K3638 Eaton Fuller Transmission Connector Kit Inertia Brake ... K3365 Eaton Fuller ... Remove the cap on the end. You will need to drain the transmission fluid and replace all the gears in the end cap if damaged hopefully they are not and you can just tighten up the nut. What happens is a nut comes loose and backs off the pressure on the bearings and you loose 5th. I removed the entire transmission and opened it up.For ATS, if you go to your control settings and change your shifter layout to "Eaton Fuller 18-speed" set buttons for "Shifter Toggel 1&2" you will be able to shift through all 18 gears. It will show up as 1L, 1H, 2L, 2H, ect. giving you all 18 gears, and the same from the 10 & 13 speeds. I don't know how to get more than 12 gears in ETS2.Eaton 10-speed Shiftand vocational models Enhanced Torque and Ratio Coverage • Torque capacities from 1450 lb-ft (1966 Nm) through 1850 lb-ft (2508 Nm) Application Specific Performance • Over-drive, direct-drive and multi-torque capabilities • Specifically configured for regional haul and over the road applications Intelligent Gear Selection7 set 2018 ... Eaton's Ultrashift Plus 18-speed transmission is arguably the simplest ... X-Y shifter. In terms of reliability, the main components have a ...

If damage is found or there are significant metal fragments in the oil, replace damaged, worn or failed transmission components. Retest operation, Go to Step A If no damage is found within the transmission main case, contact Eaton at (800) 826-4357 for further diagnostics.

Professional Shifting - 5 & 6-Speed. 3:10. Instruction on shifting Eaton's 5- and 6-speed manual transmissions for medium-duty commercial vehicles. This video highlights the benefits and features of the Eaton UltraShift PLUS transmission without optional creep mode. It also provides some of the "do's and don'ts" to help drivers be successful.

Eaton Customer Quality Group at (616) 342-3000. 5. If the tower mounted shift lever is used, it the OEM's responsibility to ensure the tower assembly is rigidly mounted. As a guideline, a minimum floor thickness in the mounting area of 0.250" for alumimum (0.125" for steel) is recommended. Shift Lever Recommenda-tionsOct 17, 2017 · For the price of trying to diagnose the problem by throwing a xy shifter, new clutch, new tcm, labor etc. you're already invested half towards a manual transmission conversion. boneebone , Oct 18, 2017 Move the range selector up to high range. Disconnect the small air line connected to the “P” port of the shift knob. Check for air flow from the. port and air line. Constant air is leaking from the “P” port or the “E” port. Repair or replace the shift knob. Air is coming out of the disconnected air line. 1.Eaton XY shifters. Home / Eaton XY shifters / Eaton XY shifters. March 25, 2017. 0. 0. Related Posts. HEAVY DUTY TYRE RE-MANUFACTURE! NOBODY LIKES WASHING DISHES! SIDEWALL DAMAGE SAFELY REPAIRED! Head Office Branch (Johannesburg) 011 973 4585 / 010 596 7959; 011 973 4181;EATON TRANS HARNESS EATON 4307347 XY SHIFTER K-4118. Harness only, no metal L-shaped bracket. See details - EATON TRANS HARNESS EATON 4307347 XY SHIFTER K-4118. See all 3 brand new listings. Buy It Now. Add to cart. Watch. Sold by pfshd_38 100.0% Positive feedback Contact seller. About this product. Product Identifiers. Brand.

DescriptionS2745R Fuller Reman XY Shifter Assembly. $1,751.47. Add to Cart. Quick view. K3638 Eaton Fuller Transmission Connector Kit Inertia Brake ... K3365 Eaton Fuller ... For the price of trying to diagnose the problem by throwing a xy shifter, new clutch, new tcm, labor etc. you're already invested half towards a manual transmission conversion. boneebone , Oct 18, 2017S2745R Fuller Reman XY Shifter Assembly. $1,751.47. Add to Cart. Quick view. K3638 Eaton Fuller Transmission Connector Kit Inertia Brake. $27.68. Add to Cart. Quick view. K4148 Eaton Fuller Speed Sensor Kit $39.94. Add to Cart. Quick view. 35-RPL25X Dana Spicer Select U-Joint Replacement for Meritor 25 ...Eaton Customer Quality Group at (616) 342-3000. 5. If the tower mounted shift lever is used, it the OEM's responsibility to ensure the tower assembly is rigidly mounted. As a guideline, a minimum floor thickness in the mounting area of 0.250" for alumimum (0.125" for steel) is recommended. Shift Lever Recommenda-tionsMay 16, 2018 · Xy-shifter Gear Select repair

Description

Professional Shifting - 5 & 6-Speed. 3:10. Instruction on shifting Eaton's 5- and 6-speed manual transmissions for medium-duty commercial vehicles. This video highlights the benefits and features of the Eaton UltraShift PLUS transmission without optional creep mode. It also provides some of the "do's and don'ts" to help drivers be successful.Genuine Eaton® New XY Transmission Shifter Assembly Reman P/N: S-2745R, HL3Z14401ZC, FULS2745R.To use the guideline, 1) Locate the transmission problem in the boxes below. 2) Hover over the box to see the possible problem and take note of the numbers next to the possible cause. 3) Refer to the list below and locate the corresponding number listed next to the problem.I am working on a volvo truck with an eaton ultrashift transmission. I wont shift over 5th gear. I have already replaced the clutch that had a failed release bearing cover along with the low inertia c. Triage Tech/Shop Foreman. Volvo vnl with eaton fuller ultrashift no "pedal clutch" I. UltraShift PLUS Service Manual - Eaton CumminsThis pdf document provides detailed instructions on how to service and troubleshoot the UltraShift PLUS automated manual transmission, which is designed for various vocational applications. Learn how to diagnose, repair, and maintain your UltraShift PLUS transmission with this comprehensive guide. UltraShift PLUS Service Manual - Eaton CumminsThis pdf document provides detailed instructions on how to service and troubleshoot the UltraShift PLUS automated manual transmission, which is designed for various vocational applications. Learn how to diagnose, repair, and maintain your UltraShift PLUS transmission with this comprehensive guide.hi,i have eaton smart shift transmision and it is giving me problems with shifting.sometimes it is working properly and sometimes it just wont go in at all.i ussually stop the trusk turn it of and than do the reset ,ahd after that i am ok for a while.(sometimes 100 miles,sometimes just 2 or 3).truck make is frghtl century 2005.most frequent problem is downshifting from 10th gear.in the place ...K Purpose: Visually identify if the shift lever is an Eaton built shift lever or an OEM built shift lever. 1. Is vehicle equipped with an Eaton supplied Shift Lever or an OEM supplied Shift Lever. 1. Key off. 2. Disconnect negative battery cable. • If Eaton Cobra Lever, go to Step L. 3. Disconnect 38-way Vehicle Harness from TECU.REMAN XY SHIFTER KIT, GEN 3 TRANSMISSION, HEAVY DUTY; ABP R26 K4223. REMAN XY SHIFTER KIT, GEN 3 TRANSMISSION, HEAVY DUTY. Find My Dealer. Retrieving price... View PDC Availability Details. Please Note, this part is on Manual Allocation in the US. Please Note, this part is on Manual Allocation in Canada.1. Starting Problem. If you have an Eaton ultrashift, you may be experiencing starting problems and annoying error codes. If your truck won't start and error codes are popping up, it may be due to a faulty Ultra-shift truck, and it's important to diagnose them as soon as possible.

Eaton has a great troubleshooting manual. If you are not shifting from low to high or from high to low, check the input sensors or the Range Solenoid Valve. I had the same problem, sometimes it would shift from 2 to 10 then when it got hot, in about 10 minutes, it would not shift. Sometimes stayed in high gear.

An update on my problems with the 2005 junk Eaton 10 spd. Two long trips and the same event sequence of events of quick reshifts in and out of 10th after about two hours on the road, then more frequent 10th gear studders, then speedo drops to 0, fault light in 10th and then eventually total lockup stuck in 10th. 4 times, like clock work, if locked in 10th after 4 hours of running.

Electrical and Industrial | Power management solutions | EatonTampa. (813) 685-6100. Shop New XY SHIFTER (GEN3) HEAVY DUTY for sale online from Weller Truck. Visit our site today for new and remanufactured truck parts and equipment.Find many great new & used options and get the best deals for Weller%2F+Eaton+Fuller+K3784rx+XY+Shifter+Gen+3+Skdb29362+Rebuilt at the best online prices at eBay! Free shipping for many products!Fault Code 52 is set when TECU has detected either an electrical failure of the X-Y Gear Position Sensor circuit or a mechanical failure within the X-Y Shifter. Detection The TECU monitors both the 5-volt X-Y Gear Position Sensor supply and the return voltage signal from the X-Y Gear Position Sensor.Aug 12, 2019 · Having problems with my Eaton ultra shift transmission. 2nd and 7th gear keeps slipping. I replaced the xy shifter and replaced the wire harness. I also replaced a bad battery. Any idea what is going on? Mechanic's Assistant: What is the complete model and serial number of your machine? 07 Volvo 760. Serial number is ***** For ATS, if you go to your control settings and change your shifter layout to "Eaton Fuller 18-speed" set buttons for "Shifter Toggel 1&2" you will be able to shift through all 18 gears. It will show up as 1L, 1H, 2L, 2H, ect. giving you all 18 gears, and the same from the 10 & 13 speeds. I don't know how to get more than 12 gears in ETS2.Oct 17, 2017 · For the price of trying to diagnose the problem by throwing a xy shifter, new clutch, new tcm, labor etc. you're already invested half towards a manual transmission conversion. boneebone , Oct 18, 2017 Main Drive Gear. When the vehicle is driven the XY Shifter Actuator position sensor indicates minimum gear engagement was . not achieved and the TECU sets Fault Code 73 FMI 7. Image below indicates order of installation for Input Shaft Spacer (Item 4): Item Description Part Number 1 Input Shaft - 2 Seal - 3 Snap Ring 14750Issue Description: Worn or loose X-Y shifter internal components can cause incorrect values to be saved to the TECU during the power-down calibration. Symptoms from this incorrect calibration may cause the following: Driver reported shifting issues, harsh or missed shifts.

REMAN XY SHIFTER KIT, GEN 3 TRANSMISSION, HEAVY DUTY; ABP R26 K4223. REMAN XY SHIFTER KIT, GEN 3 TRANSMISSION, HEAVY DUTY. Find My Dealer. Retrieving price... View PDC Availability Details. Please Note, this part is on Manual Allocation in the US. Please Note, this part is on Manual Allocation in Canada.Find many great new & used options and get the best deals for Eaton Fuller Transmission Parts Gen Generation 2 XY Shifter at the best online prices at eBay! Free shipping for many products!Mar 31, 2015 · Truck Repair. I have a 2007 Freightliner Columbia, ultra shift. Has problems…. Answered in 32 minutes by: The dealers use a program called Eaton Service Ranger which will pull the trouble codes and assist in doing the various pinpoints that are needed to diagnose the fault. What makes the F code so bad is the fact that it just mean failure. Instagram:https://instagram. sanrio cute wallpaperiphykansas ku basketballcharlie o'brien Tampa. (813) 685-6100. Shop New XY SHIFTER (GEN3) HEAVY DUTY for sale online from Weller Truck. Visit our site today for new and remanufactured truck parts and equipment. the frieze of the parthenonwhats the score of the ku game Eaton has a great troubleshooting manual. If you are not shifting from low to high or from high to low, check the input sensors or the Range Solenoid Valve. I had the same problem, sometimes it would shift from 2 to 10 then when it got hot, in about 10 minutes, it would not shift. Sometimes stayed in high gear. vintage metal tv tray tables Professional Shifting - Performance 13 & 18 Speeds. 5:21. How to professionally shift Eaton's heavy-duty 13- and 18-speed manual transmissions for commercial vehicles. Eaton UltraShift Plus transmission features animation.The system can identify an issue with the X-Y Shifter Gear Motor circuit, the TECU gear motor controller or the power and ground connections to the TECU under the following conditions: ... contact Eaton at (800) 826-4357 for repair strategy. If FMI 12 set, replace Transmission Electronic Control Unit (TECU) C. Go to Step V. V. Purpose: Verify ...